Characteristic & main applications Excellent conformity with flange surfaces at low surface stress. For applications with low available bolt loads.
Material Synthetic fibres and cork, bonded with NBR.
pT diagram
The Klinger pT diagram provides guidelines for determining the suitability of a particular gasket material for a specific application based on the operating temperature and pressure only. Always refer to the chemical resistance of the gasket to the fluid.
Technical Data
Typical values for 2 mm thickness
Compressibility ASTM F 36 J
%
30
Recovery ASTM F 36 J
min.
%
50
Stress relaxation DIN 52913
25 MPa, 16 h/100 °C
MPa
15
Klinger cold/hot compression 25 MPa
thickness decrease at 23 °C
%
16
thickness decrease at 200 °C
%
22
Tightness according DIN 3535/6
ml/min
0,1
Thickness increase after fluid immersion ASTM F 146